SurgeX Branch Circuit Surge Eliminator And Power Conditioner - PF-420 - image 1

SurgeX Branch Circuit Surge Eliminator And Power Conditioner - PF-420

Prijs met korting  $1,934.00 Normale prijs $3,869.00
Ga direct naar de productinformatie
SurgeX Branch Circuit Surge Eliminator And Power Conditioner - PF-420 - image 1

SurgeX Branch Circuit Surge Eliminator And Power Conditioner - PF-420

Prijs met korting  $1,934.00 Normale prijs $3,869.00

Product Details
SurgeX Branch Circuit Surge Eliminator And Power Conditioner - PF-420
The SurgeX Branch Circuit lineup provides guaranteed whole room surge protection and conditioning for audio, video, and mission critical equipment at the service panel. Available in two configurations, these solutions are built with NEMA magnetic shielding steel enclosures that meet code for use at the service entrance, sub-panels, and in ceiling plenums.
Engineered with Advanced Series Mode surge elimination and power conditioning technologies, they eliminate all surge energy to properly protect connected equipment from surges, spikes, and electrical transients without producing harmful ground contamination or common-mode disturbances. An all mode impedance tolerant EMI/RFI filter virtually eradicates electrical noise to offer a complete whole room power conditioning solution.
Specifications
Load Rating: 20A (x4)
Voltage Rating: 120V
Power Requirement (no load): 4 W
Surge Let-through Voltage (6000 Volt Surge): 0 Volts
Maximum Applied Surge Voltage: 6000 Volts *
Maximum Applied Surge Current: Unlimited (due to current limiting) *
Maximum Applied Surge Energy: Unlimited (due to current limiting) *
Endurance (C62.41-1991 category B3 pulses): 1 KV > 500,000; 3 KV > 10,000; 6 KV > 1000
EMI/RFI Filter
Normal mode (50 ohm load): > 20 dB, 39 kHz – 50 MHz > 30 dB, 150 kHz – 50 MHz 25 dB @ 100 kHz; 45 dB @ 300 kHz; 67 dB @ 3 MHz; 35 dB @ 30 MHz
Common Mode ( 50 ohm load): > 10 dB, 290 kHz – 50 MHz > 20 dB, 1.9 MHz - 7.875 MHz > 30 dB, 4.2 MHz – 5.125 MHz 10 dB @ 300 kHz; 17 dB @ 1 MHz; 30 dB @ 5 MHz; 14 dB @ 20 MHz
Under-Voltage Auto Shutdown: No
Over-Voltage Auto Shutdown: No
Over-Current Auto Shutdown: None
Over-Temperature Auto Shutdown: None
Measurement Accuracy
Voltage: NA
Current: NA
Power: NA
Energy: NA
Temperature: NA
Network Port: No
Serial Port: None
Temperature Sensor Input: None
Auxiliary Relay Outputs: No
Contact Closure Input: No
Temperature Range: 5C to 35C
Humidity Range: 5% to 95% R.H. Non-condensing
Agency Listings: Conforms to UL Std 1283 Certified to CSA Std C22.2 No. 8
* 1.2 x 50 microsecond industry standard combination wave surge as per IEEE C62.41 ** Specifications subject to change without notice
Approximate Dimensions
Height: 16"
Width: 12"
Depth: 4"
Approximate Weight
Unit: 30 lbs
Shipping: 35 lbs
Read More
California customers
Proposition 65 WARNING
WARNING: Cancer and Reproductive Harm

Specifications
General
Color
Black
USB Ports
No
Approximate Weight
Package Weight (lbs)
31
Approximate Dimensions
Package Size HxWxL (in)
7 x 15 x 21

30 Days Return Policy